APC EPDU1132B Basic Rack PDU 0U
Basic vertical rack distribution rated at 7360 VA with 20 C13 and 4 C19 outlets. A 32 A IEC input and 2.99 m cable support cabinet power planning.
Original price was: 1,350.22 SAR.1,269.21 SARCurrent price is: 1,269.21 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
APC EPDU1132B is a Basic Rack PDU for cabinets that need a defined electrical distribution point and a vertical mounting arrangement. Its 7360 VA load capacity, single-phase input and mixed IEC outlets make the purchasing decision practical: match the cabinet supply, equipment leads and planned load before installation. This model concentrates on basic distribution within the family, while the metered versions address a different operating requirement. For a facilities manager equipping a server room, branch communications cabinet or security equipment rack, the appeal is a straightforward power layout that leaves the rack mounting positions available for equipment. Select it around the electrical design of the cabinet rather than the outlet count alone.
APC EPDU1132B for basic rack distribution
The input current limit and maximum current draw are 32 A. Input voltage options are 200 V, 208 V and 230 V, with a specified output voltage of 230 V and frequency of 50/60 Hz. The input connection is IEC 60309 32 A 2P + E. These details belong in the handover between the IT team and the electrical contractor: the upstream connection must suit the unit, and the planned equipment demand must remain within the electrical limits. Treat the 7360 VA figure as a capacity boundary when preparing the cabinet load schedule.
Match the outlets to the equipment
The outlet arrangement comprises 20 IEC 60320 C13 connections and 4 IEC 60320 C19 connections. A mixed cabinet can therefore be planned around the actual connector needs of its devices rather than assuming every power lead ends in the same fitting. Before ordering, identify which equipment will use each outlet type and check the corresponding leads. Having an unused outlet does not establish that additional load is available. Review the connected demand as well as the physical connection plan whenever equipment is added or moved between cabinets.
Keep the cabinet layout workable
Vertical side mounting and the 0U format place distribution beside the equipment area. The body measures 1175 mm high, 62 mm wide and 44.4 mm deep, with a net weight of 3.58 kg. Use those dimensions to check the available side space, cable access and clearance before assigning a mounting position. The supply cable is 2.99 m long. Measure its intended route from the cabinet to the supply connection, allowing for the actual path through cable management rather than relying on a straight-line distance across the room.
Where it fits in Saudi facilities
In an office communications room, this unit can provide a common distribution location for compatible rack equipment. In a retail branch or logistics facility, it suits planning where the cabinet is maintained as a local installation and the purchasing brief calls for basic distribution. A security operations team can assess it for its equipment rack by checking connector types and the combined electrical demand of the installed devices. These are cabinet applications: the deciding factors remain the supply connection, mounting clearance and equipment load, regardless of the business sector using the room.
Choose between the family members
EPDU1132M is the named metered alternative when remote monitoring is part of the operating brief. EPDU1216M is another metered option to assess when the site’s supply design calls for a different electrical arrangement. EPDU1132B belongs on the shortlist when the requirement is basic rack power distribution. Settle that operational requirement before comparing individual connections: a cabinet that needs remote oversight should be specified around that need, while a basic installation can be assessed directly against its electrical and mechanical fit.
Installation environment and handover
The operating temperature range is 0 to 45 °C, and operating relative humidity is 5 to 95%. Check the conditions at the intended cabinet position, especially where distribution sits beside equipment exhaust paths. The storage temperature range is -25 to 65 °C, which should be considered separately from operating conditions during project staging. The warranty period is 12 months. At handover, retain the cabinet load schedule, identify the supply connection and leave the outlet allocation clear for subsequent service work. This makes future equipment changes easier to assess against the same installation limits.
Package Contents
- Installation guide
- Toolless mounting kit
- Vertical mounting brackets
Technical Specifications
- Brand
- APC
- Warranty
- 1 Year
- Model
- EPDU1132B
- Mounting
- RACK-MOUNTED
- Power
- 7360 VA
Frequently Asked Questions
What kind of PDU is this?
EPDU1132B is a basic rack PDU with single-phase input and 7360 VA capacity.
Which outlets does it provide?
It has 20 IEC 60320 C13 outlets and 4 IEC 60320 C19 outlets.
How does it mount?
It mounts vertically on the rack side in a 0U arrangement. The supply cable is 2.99 m long.
Which input connection is required?
The input connection is IEC 60309 32 A 2P + E.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC AP7821B Metered Rack PDU, 16A, 1U, 8 x C13
On backorder
APC AP7820B Metered Rack PDU, 1U, 8 x C13 Outlets
On backorder
APC AP6032A Rack PDU, 4 C19 Outlets, 32A IEC 60309 Input
On backorder
APC ER7PDUBRKT Double-Width PDU Mounting Brackets, Black
On backorder





Reviews
There are no reviews yet.