APC EPDU1232B Basic Rack PDU 22000 VA
Basic rack power distribution rated at 22000 VA, with 30 C13 and 12 C19 outlets. Its vertical 0U format mounts along the rack side and uses a 400 V three-phase supply.
Original price was: 3,300.53 SAR.3,102.50 SARCurrent price is: 3,102.50 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
APC EPDU1232B brings 22000 VA of basic power distribution to a rack through a vertical, side-mounted 0U layout. Its combination of 30 IEC 60320 C13 outlets and 12 IEC 60320 C19 outlets suits a cabinet containing equipment with different power connector requirements. For a facilities or operations team planning a server room, the main selection questions are whether the incoming supply matches the unit, whether the connected equipment matches its outlet types, and whether the cabinet has the required side clearance. This model accepts a 400 V three-phase supply and provides 230 V output. Choose it when the project calls for a basic rack PDU with this electrical capacity and a substantial mix of equipment connections.
APC EPDU1232B in a populated cabinet
The vertical format keeps the distributor alongside the equipment rather than occupying the horizontal rack positions used for servers and network hardware. That makes its physical layout relevant when adding power connections to an already planned cabinet. The body measures 1794 mm high, 62 mm wide and 44.4 mm deep, so check the available mounting height and side space against the cabinet drawing. Its net weight is 5.14 kg. Leave access to the sockets and cable routes when deciding which side of the cabinet will carry the unit.
The C13 and C19 outlet mix lets the installer plan separate cable groups according to the connectors on the connected equipment. Match each equipment power cord to the appropriate socket before installation. Outlet availability and electrical capacity are separate checks: having an unused socket does not establish that another load can be added. Build the load schedule around the equipment demand and the distributor rating, then keep that schedule with the cabinet documentation for later changes.
Supply and load planning
The input connection is IEC 60309 32 A 3P + N + PE, with a maximum current draw of 32 A. The frequency rating is 50/60 Hz. These details make the upstream electrical connection a project requirement, rather than a choice to resolve after the cabinet arrives. Have the electrical contractor confirm the matching supply connection, neutral and protective earth arrangement, circuit provision and intended equipment loading. The 22000 VA rating expresses apparent power; use the actual load characteristics when preparing the electrical schedule.
A 1.9 m supply cable makes the position of the supply point part of the rack plan. Trace the intended route around the cabinet structure and existing cabling rather than relying only on the straight-line distance to the socket. Keep the connection accessible for installation and servicing. The output is 230 V, so confirm that the equipment receiving power is suitable for that output before allocating its connection.
Position within the APC family
Capacity distinguishes this model from the EPDU1132B and EPDU1132M, each rated at 7360 VA, and the EPDU1216M, rated at 11000 VA. The EPDU1232B is the higher-capacity choice in that comparison. Select according to the planned rack load and incoming supply, rather than matching the family name alone. Its basic PDU role also differs from the PDM1332IEC-3P power distribution module: the EPDU1232B presents C13 and C19 connections along the rack for equipment power cords.
Site conditions and installation handover
Saudi data rooms, enterprise server cabinets and communications rooms can use this arrangement where the supply and rack layout meet the unit’s requirements. In a hospital support room or industrial administration building, include the PDU in the cabinet design and electrical review before equipment is delivered. The operating temperature range is -5 to 45 °C. Assess the conditions at the installed location inside the cabinet, especially where warm equipment exhaust may affect the surrounding air.
Plan the mechanical installation around side mounting and the vertical orientation. Use the installation guide when arranging the mounting hardware, and retain access for future cable changes. At handover, record which equipment uses each connection and review the load plan whenever equipment is replaced. The warranty period is 1 Year. Keeping the model, cabinet position and electrical assignment together helps purchasing, facilities and IT teams identify the installed unit when coordinating maintenance or a later expansion.
Package Contents
- Installation guide
- Toolless mounting kit
- Vertical mounting brackets
Technical Specifications
- Brand
- APC
- Warranty
- 1 Year
- Model
- EPDU1232B
- Mounting
- Vertical rack mount, zero U
- Power
- 22 kW
Frequently Asked Questions
What supply does the EPDU1232B require?
It accepts 400 V three-phase power through an IEC 60309 32 A 3P + N + PE input connection and provides 230 V output.
Which equipment outlets does it have?
It has 30 IEC 60320 C13 outlets and 12 IEC 60320 C19 outlets.
Does it occupy horizontal rack space?
Its mounting format is vertical, side-mounted 0U. Check the cabinet against its 1794 mm height, 62 mm width and 44.4 mm depth.
How does its capacity compare with EPDU1216M?
EPDU1232B is rated at 22000 VA; EPDU1216M is rated at 11000 VA.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC AP4424A Rack Transfer Switch 2U 32A, 18 Outlets
On backorder
APC APDU9959EU3 Switched Rack PDU, 16A 230V, IEC309 Cord
On backorder
APC AP8886 Metered Rack PDU, 32A Three-Phase 400V
On backorder
APC APDU9959NA3 Switched Rack PDU, 20A 208V, L620 Cord
On backorder





Reviews
There are no reviews yet.