APC PDM3516IEC-440 Power Distribution Module, 16A, 440 cm
An APC three-phase 16 A power distribution module on a 440 cm cable, ending in one IEC 309 16 A outlet for racks that stand close to their power source.
Original price was: 2,785.45 SAR.2,618.32 SARCurrent price is: 2,618.32 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC PDM3516IEC-440 is a three-phase power distribution module that takes a 400 V supply, protects it with a 16A breaker and delivers it to a rack through a single IEC 309 16 A outlet at the end of a 440 cm cable. That lead is the shortest of the PDM3516IEC-440, PDM3516IEC-500 and PDM3516IEC-560 trio, which makes this the model for a cabinet standing right beside its panel or directly beneath an overhead feed. It pairs a moderate current rating with a short run: 16 A maximum line current and maximum current draw, a 50 Hz rating, and output listed at 230 V and at 400 V three-phase. For network, security and edge racks that need a dedicated three-phase circuit but not a heavy one, it does the job without paying for current or cable the site will never use. The grey assembly carries CE and VDE marks.
How the APC PDM3516IEC-440 delivers power to the rack
A rack circuit built on site involves several trades: someone fits a breaker in the panel, someone pulls and terminates the cable, someone mounts an industrial socket at the cabinet. The PDM3516IEC-440 replaces those steps with one assembly. Breaker, cable and outlet arrive together, so the circuit that reaches the first rack is identical to the one that reaches the tenth, and replacing it later means unplugging one part and fitting another.
At the source, the module works on a 400 V three-phase supply at 50 Hz. Each line is rated for up to 16 A, and the 16A breaker sets the ceiling for everything downstream. At the rack, the IEC 309 16 A outlet accepts a matching industrial plug, typically the input lead of a rack PDU that then fans power out to individual devices. The output is listed at 230 V and at 400 V three-phase; check which of the two the connected rack PDU expects before ordering.
IEC 309 connectors are made in distinct ratings and pin layouts, so the outlet only accepts a plug built for it. That matters in shared rooms where contractors and in-house staff work side by side: a plug of the wrong rating simply will not seat.
Where it fits in Saudi facilities
A 16 A three-phase circuit over a short lead suits rooms where equipment is modest in load but critical in function. Security operations rooms are a clear example: the racks holding video recorders, access control servers and network switches for a mall, a hospital campus or a government complex usually sit in a small room with the distribution board on the wall a short step away. The same layout appears in the floor communication rooms of office towers in Riyadh and Jeddah, in the server rooms of bank branches, and in school and university IT rooms.
In oil, gas and petrochemical plants in the Eastern Province, field instrument and telecom rooms often hold a single rack next to its panel, and a short factory-made lead is easier to inspect than one fabricated on site. Telecom operators’ edge and aggregation sites follow the same pattern of compact rooms and short distances.
Choosing between the PDM3516IEC-440 and its siblings
Within this group the electrical rating stays fixed while the cable grows: the PDM3516IEC-500 and PDM3516IEC-560 carry the same electrical design on longer leads. If the measured route fits within 440 cm, extra cable buys nothing. Surplus has to be coiled somewhere, and a coil inside a cabinet or under a raised floor obstructs airflow and makes the circuit harder to trace.
For racks whose load outgrows this circuit, the PDM3532IEC models step up to a higher current rating. The PDX332IEC-1080, with its 2P + E input, serves single-phase supplies instead. The PDM3516IEC-440 remains the choice for a nearby rack whose load stays within 16 A per phase.
Deployment notes for the PDM3516IEC-440
Measure the actual route, not the straight-line distance. Start at the panel, follow the cable tray or underfloor path, include every rise and bend, and finish at the point inside the cabinet where the rack PDU plug will sit. If that total stays inside 440 cm with a little slack for a service loop, this is the right length; if it does not, move up to the PDM3516IEC-500.
Confirm that the supply is three-phase 400 V at 50 Hz, and that the rack PDU or equipment it will feed carries an IEC 309 16 A plug of the matching configuration. Plan the rack load phase by phase so that no line approaches its 16 A rating. The module comes with an installation guide and is covered by a 12-month warranty, and its CE and VDE marks can go straight into the submittal file for consultants and facility owners.
Package Contents
- Power distribution module
- Installation guide
Technical Specifications
- Brand
- APC
- Warranty
- 1 Year
- Model
- PDM3516IEC-440
Frequently Asked Questions
What supply does the APC PDM3516IEC-440 connect to?
A 400 V three-phase supply at 50 Hz. Maximum line current and maximum current draw are both 16 A, and the circuit is protected by a 16A breaker.
What plugs into its outlet?
Its single IEC 309 16 A outlet accepts a matching IEC 309 16 A plug, usually the input lead of a rack PDU.
When is a longer model the better choice?
When the measured route from the source to the rack, including rises and bends, is longer than 440 cm. The PDM3516IEC-500 and PDM3516IEC-560 share the same electrical design with longer cables.
What warranty and markings does it carry?
It is covered by a 12-month warranty and carries CE and VDE marks.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC AP7821B Metered Rack PDU, 16A, 1U, 8 x C13
On backorder
APC APDU9959EU3 Switched Rack PDU, 16A 230V, IEC309 Cord
On backorder
APC AP7822B Metered Rack PDU, 32A, 2U, C13 and C19
On backorder
APC ER7PDUBRKTS Single-Width PDU Mounting Bracket Kit
On backorder





Reviews
There are no reviews yet.