APC PDM3532IEC-260 Power Distribution Module, 32 A, 260 cm

A three-phase APC power distribution module that brings a 400 V, 32 A feed to one rack over a 260 cm cable ending in an IEC 309 32 A connector, protected by a 32A breaker.

ModelPDM3532IEC-260

Original price was: 2,755.44 SAR.Current price is: 2,590.11 SAR. excl. VAT

Available on backorder

WhatsApp Inquiry

RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.

Wholesale and project supply — up to 45% off

Minimum order5 units

Shipping and delivery icon
Fast shipping
SMSA Express logoFedEx logoNAQEL Express logoDHL logo
Product warranty icon
Genuine warranty
All products carry a one-year authorised-agent warranty.
Secure payment icon
Secure payment
madaVisaMastercardApple Pay
B2B sales icon
B2B/B2C supply

Up to 45% off wholesale supply.

Overview

The APC PDM3532IEC-260 is a power distribution module that carries a 400 V three-phase supply to a single rack over a 260 cm output cable, ending in one IEC 309 32 A connector. Its place in the PDM3532IEC series is the balanced, close-coupled position: the cable is long enough to cross from a distribution point to a neighbouring rack, yet short enough that there is little surplus to coil under a raised floor or behind a cabinet. Of the PDM3532IEC-260, PDM3532IEC-320 and PDM3532IEC-380, it has the shortest run, which makes it the natural pick where the source and the load sit a short distance apart. The module is protected by a 32A breaker, is rated for a maximum line current of 32 A at 50 Hz, and comes in grey.

What the APC PDM3532IEC-260 does in practice

A three-phase rack feed has three jobs: deliver the right voltage, stop at a safe current, and arrive on a connector that a passing tug cannot pull loose. The PDM3532IEC-260 handles all three in one assembly. Its input is 400 V three-phase, and its output is listed at 230 V and 400 V three-phase, the pairing a low-voltage three-phase system provides: 400 V between any two phases and 230 V from each phase to neutral. A rack PDU built for a three-phase input therefore receives its supply directly and distributes it to the equipment in the rack.

The 32A breaker sets the ceiling for the whole branch. The maximum current draw is 32 A, and a load beyond that opens the breaker before the cable or connector is pushed past its rating. At the far end, the single IEC 309 32 A outlet belongs to the industrial pin-and-sleeve connector family used for high-current feeds, a job a domestic plug is not designed for. One outlet means one load: the module feeds one rack PDU, so every rack gets its own protected branch and a fault in one rack stays in that rack.

Where it fits in Saudi facilities

Bank and fintech data rooms in Riyadh, hospital server rooms in Jeddah and Dammam, telecom operator equipment halls, and the government data centres expanding under the Kingdom’s digital transformation programmes share a common layout: power arrives at a three-phase distribution point, and racks are lined up close to it. In rows where the first racks stand within reach of a 260 cm cable, the PDM3532IEC-260 is the natural choice. Colocation providers building out tenant cages can standardise on it for the positions nearest the power source and keep longer modules for the far end of the row.

Industrial sites are a second fit. Petrochemical plants in Jubail and Yanbu, desalination control rooms and logistics hubs run control and SCADA servers in small rack groups beside their electrical rooms. A protected 32 A three-phase feed on an IEC 309 connector matches the industrial wiring practice their electrical teams already work with.

Choosing between the PDM3532IEC-260 and its siblings

The deciding question in this series is distance. The PDM3532IEC-320 and PDM3532IEC-380 carry longer cables for racks set further from the source; the PDM3532IEC-260 is the one to choose when the rack is close and extra cable would only end up coiled. Measure the actual route before ordering, including the rise from the floor void or cable tray into the rack. A module that is too short cannot be lengthened in place without adding a joint, and one that is far too long leaves a loop that obstructs airflow.

Further along the family, the PDM3532IEC models from the PDM3532IEC-380 upward run on the same 400 V three-phase supply, as do the PDPM138H-5U and PDPM277H, so combining them in one room does not change the upstream design. Single-phase racks belong to a different branch of the family: the AP7822B, for example, takes an IEC 60309 32 A 2P + E input and outputs 230 V. Choose the PDM3532IEC-260 when the rack PDU itself expects a three-phase input on an IEC 309 32 A connector.

Deployment notes

Prepare the upstream circuit for 400 V three-phase at 32 A, and have your electrical engineer confirm the facility’s supply frequency against the module’s 50 Hz rating. Keep the combined load of the rack PDU it feeds within the 32 A maximum current draw, and leave headroom rather than running the breaker at its limit. Route the 260 cm cable so the IEC 309 connector stays reachable for isolation during maintenance and carries no strain, and follow the installation guide when fixing the module in place. The module carries CE and VDE marks, is RoHS compliant by exemption, and is covered by a 12-month warranty.

Package Contents

  • Power distribution module
  • Installation guide

Technical Specifications

Brand
APC
Warranty
1 Year
Model
PDM3532IEC-260

Frequently Asked Questions

What supply does the APC PDM3532IEC-260 take?

A 400 V three-phase supply at 50 Hz, with a maximum line current of 32 A. Its output is listed at 230 V and 400 V three-phase.

What connector is at the end of the cable?

One IEC 309 32 A connector at the end of a 260 cm output cable, so the module feeds a single rack PDU.

How is the circuit protected?

By a 32A breaker that matches the module's 32 A maximum current draw.

When should I choose the PDM3532IEC-320 or PDM3532IEC-380 instead?

When the measured route from the distribution point to the rack is longer than the 260 cm cable of this model can cover; both of those models carry longer cables.

What certifications and warranty apply?

It carries CE and VDE marks, is RoHS compliant by exemption, and has a 12-month warranty.

Brand
APC

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and

Browse brand products
Shipping, Warranty and Regulatory

Delivery across Saudi Arabia

Clear warranty

Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.

Customer Reviews

No ratings yet for this product

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

APC

APC ER7PDUBRKTS Single-Width PDU Mounting Bracket Kit

Model ER7PDUBRKTS
Original price was: 110.98 SAR.Current price is: 104.32 SAR. excl. VAT Save 6.66 SAR

On backorder

Request a Quote
APC

APC AP7921B Switched Rack PDU, 16 A, 1U, 8 C13 Outlets

Model AP7921B
1UEthernet network port
Original price was: 3,300.53 SAR.Current price is: 3,102.50 SAR. excl. VAT Save 198.03 SAR

On backorder

Request a Quote
APC

APC AP7821B Metered Rack PDU, 16A, 1U, 8 x C13

Model AP7821B
2 Years1U230V
Original price was: 2,280.36 SAR.Current price is: 2,143.54 SAR. excl. VAT Save 136.82 SAR

On backorder

Request a Quote
APC

APC AP6032A Rack PDU, 4 C19 Outlets, 32A IEC 60309 Input

Model AP6032A
230V
Original price was: 850.14 SAR.Current price is: 799.13 SAR. excl. VAT Save 51.01 SAR

On backorder

Request a Quote

Original price was: 2,755.44 SAR.Current price is: 2,590.11 SAR. excl. VAT