APC PDM3532IEC-380 Power Distribution Module, 380 cm Cable
An APC power distribution module with a 380 cm output cable that takes a protected 400 V three-phase, 32 A feed to racks further from the source through one IEC 309 32 A connector.
Original price was: 2,810.45 SAR.2,641.82 SARCurrent price is: 2,641.82 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC PDM3532IEC-380 brings a protected 400 V three-phase supply to a rack that stands further from its power source than a short module can reach. Its 380 cm output cable ends in one IEC 309 32 A connector, and a 32A breaker guards the branch. Of the PDM3532IEC-260, PDM3532IEC-320 and PDM3532IEC-380, it has the longest cable, while the electrical rating stays identical across all three. That makes it the balanced answer for racks deeper in a row or across an aisle: enough reach to cover the distance without relocating the distribution point or adding a joint in the run. It is rated for a maximum line current of 32 A at 50 Hz and comes with its installation guide.
Why reach matters with the APC PDM3532IEC-380
A three-phase feed that falls short is not a small problem. The options are to move the rack, move the distribution, or add a connection in the run, and each one costs time or adds a possible point of failure. A cable that reaches cleanly, routed through the tray or floor void and up to the PDU inlet, avoids all three. The PDM3532IEC-380 provides the extra length in the module’s own cable, so the circuit from breaker to connector stays one continuous assembly.
Surplus has a cost too, if a smaller one: cable coiled under a raised floor gets in the way of the cold-air path. Choose this length when the route genuinely needs it, not as a default for every rack in the room.
Electrical profile
Input is 400 V three-phase at 50 Hz, and the output is listed at 230 V and 400 V three-phase, the two voltages a three-phase system offers, phase to neutral and phase to phase. Maximum line current and maximum current draw are both 32 A, matched by the 32A breaker. The single IEC 309 32 A outlet means one module per rack PDU, each rack with its own protection and its own point of isolation.
Sector fit in the Kingdom
Large rooms are where the extra reach pays off: the enterprise data halls of banks and insurers, operations centres run by utilities and transport authorities, and the server floors of the giga-project developments, where rows are long and distribution points are fixed early in the build. The PDM3532IEC-380 also suits retrofits in older government and university buildings, where the available three-phase distribution may sit in one corner of the room and racks have to go wherever floor loading and cooling allow.
Where it sits among PDM3532IEC models
If the route is shorter, the PDM3532IEC-320 or PDM3532IEC-260 will spare you the surplus cable. The series continues with models from the PDM3532IEC-440 to the PDM3532IEC-980, which also run on a 400 V three-phase supply, so a room can mix lengths without changing its upstream design.
Installation points
Size the upstream circuit for 400 V three-phase at 32 A and confirm the facility frequency against the 50 Hz rating. Measure the full route, and choose this model when it needs more than the PDM3532IEC-320 can give but fits within 380 cm with allowance for bends. Keep the rack load below the 32 A limit so there is headroom, leave the IEC 309 connector accessible for isolation, and secure the cable so the connector does not carry its weight. The module is grey, carries CE and VDE marks, and has a 12-month warranty.
Package Contents
- Installation guide
Technical Specifications
- Brand
- APC
- Warranty
- 1 Year
- Model
- PDM3532IEC-380
- Power
- 400 V 3 PHASES
Frequently Asked Questions
What makes the APC PDM3532IEC-380 different from the PDM3532IEC-260 and PDM3532IEC-320?
Its output cable is the longest of the three, at 380 cm; the 400 V three-phase input and 32 A rating are the same across all three.
What connector does the cable end in?
One IEC 309 32 A connector, which feeds a single rack PDU.
What protection is built in?
A 32A breaker that matches the module's 32 A maximum current draw.
What supply frequency is it rated for?
It is rated for 50 Hz networks, so confirm the facility supply against that rating.
What warranty and marks apply?
A 12-month warranty, and the module carries CE and VDE marks.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC AP7922B Switched Rack PDU, 32 A, 2U, 16 C13 Outlets
On backorder
APC EPDU1116S Switched Rack PDU 16A, 20 C13 and 4 C19
On backorder
APC AP6015A 1U Rack PDU, 8 C13 Outlets, 15A Input
On backorder
APC AP4423A Rack Transfer Switch 1U 16A, 3700 VA
On backorder





Reviews
There are no reviews yet.