APC PDM3516IEC-500 Power Distribution Module, 16A, 500 cm

An APC 16 A three-phase power distribution module with a mid-length 500 cm cable and one IEC 309 16 A outlet, for racks set a few positions from their panel.

ModelPDM3516IEC-500

Original price was: 2,810.45 SAR.Current price is: 2,641.82 SAR. excl. VAT

Available on backorder

WhatsApp Inquiry

RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.

Wholesale and project supply — up to 45% off

Minimum order5 units

Shipping and delivery icon
Fast shipping
SMSA Express logoFedEx logoNAQEL Express logoDHL logo
Product warranty icon
Genuine warranty
All products carry a one-year authorised-agent warranty.
Secure payment icon
Secure payment
madaVisaMastercardApple Pay
B2B sales icon
B2B/B2C supply

Up to 45% off wholesale supply.

Overview

Racks rarely line up neatly beside their power source. Once a cabinet sits a few positions along the row, the shortest lead stops reaching, and that is where the APC PDM3516IEC-500 comes in. Its 500 cm cable carries a three-phase 400 V circuit from the source to the rack and ends in one IEC 309 16 A outlet, with a 16A breaker protecting the run. The rating is deliberately moderate: 16 A maximum line current and maximum current draw at 50 Hz, with output listed at 230 V and at 400 V three-phase. That combination fits network, surveillance and light compute racks that deserve their own three-phase feed but do not draw heavily. Between the PDM3516IEC-440 and the PDM3516IEC-560, it is the middle length. The assembly is grey and marked CE and VDE.

APC PDM3516IEC-500 rating and connector

Supply side

The module expects a 400 V three-phase supply at 50 Hz. Each of the three lines is rated at 16 A, and the maximum current draw of the module is the same 16 A. The 16A breaker is what trips if the connected load goes beyond that, so the working rule is simple: add up what the rack PDU will feed on each phase, and keep every phase comfortably under the rating, leaving room for start-up surges and future additions.

Rack side

A single IEC 309 16 A outlet terminates the cable. IEC 309 industrial connectors come in fixed combinations of rating and pin arrangement, and only a plug designed for that combination will mate with the outlet, which keeps a higher-rated or differently wired lead from being connected by mistake. Both 230 V and 400 V three-phase appear as output ratings, so the rack PDU chosen for the cabinet should be matched to the voltage its own input expects.

Matching cable length to the route

Length is the only thing that separates the PDM3516IEC-500 from the PDM3516IEC-440 and the PDM3516IEC-560; rating, breaker, outlet, frequency and markings are the same across all three. The choice therefore comes down to a tape measure. The PDM3516IEC-440 is a little shorter and suits a rack right beside its source, while the PDM3516IEC-560 is a little longer for cabinets further along. Pick the PDM3516IEC-500 when the measured route, including the drop from an overhead tray or the rise from under a raised floor, lands between them.

Ordering the right length has practical value beyond tidiness. A lead pulled tight across tray edges strains its terminations, and a lead with metres to spare ends up coiled behind equipment, where it traps heat and hides labels. For heavier racks, the PDM3532IEC models offer a higher current rating, and the choice between the two series should follow the load calculation before length is considered.

Saudi sites suited to the 500 cm lead

Medium-sized equipment rooms with a single row of cabinets are typical: the server room of a regional hospital in Qassim or Asir, the IT room of a logistics hub near Dammam port, or the main communications room of a hotel in Makkah or Madinah, where the board sits at the end of the row and the second and third racks need a lead slightly longer than the first. Security integrators building central monitoring rooms for retail chains and residential compounds face the same geometry, with recorder, storage and switching racks lined up a few positions from the panel.

Racks of moderate load in schools, universities and ministry branch offices that host their own systems are also well served by a 16 A three-phase circuit, and standardising on one module type in a few lengths keeps spares and documentation simple across many sites.

Commissioning the PDM3516IEC-500

Before installation, confirm on the drawings that the source is a 400 V three-phase, 50 Hz supply and that the equipment at the rack carries an IEC 309 16 A plug in a matching configuration. Route the cable along its tray or underfloor path, fix it so its weight does not hang on the outlet, and label both ends with the circuit reference used on the panel schedule. Keep the installation guide with the room records; the module is covered by a 12-month warranty.

Package Contents

  • Power distribution module
  • Installation guide

Technical Specifications

Brand
APC
Warranty
1 Year
Model
PDM3516IEC-500

Frequently Asked Questions

How does the APC PDM3516IEC-500 differ from the PDM3516IEC-440?

Only in cable length: the PDM3516IEC-440 is shorter. The rating, breaker and outlet are the same on both. This model has a 500 cm cable.

How much current can it carry?

Maximum line current and maximum current draw are both 16 A on a 400 V three-phase, 50 Hz supply, and a 16A breaker protects the circuit.

Which voltages are available at the outlet?

Output is listed at 230 V and at 400 V three-phase, delivered through one IEC 309 16 A outlet.

Should I pick a PDM3532IEC model instead?

Choose a PDM3532IEC model when the rack load calls for a higher current rating. This module suits loads that stay within 16 A per phase on a route of around 500 cm.

Brand
APC

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and

Browse brand products
Shipping, Warranty and Regulatory

Delivery across Saudi Arabia

Clear warranty

Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.

Customer Reviews

No ratings yet for this product

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

APC

APC AP8958EU3 0U Rack PDU 16A 230V with IEC309 Cord

Model AP8958EU3
0U7 IEC-320-C13 and 1 I...230V
Original price was: 5,350.86 SAR.Current price is: 5,029.81 SAR. excl. VAT Save 321.05 SAR

On backorder

Request a Quote
APC

APC AP6015A 1U Rack PDU, 8 C13 Outlets, 15A Input

Model AP6015A
1U horizontal design240V
Original price was: 295.05 SAR.Current price is: 277.35 SAR. excl. VAT Save 17.70 SAR

On backorder

Request a Quote
APC

APC AP6032A Rack PDU, 4 C19 Outlets, 32A IEC 60309 Input

Model AP6032A
230V
Original price was: 850.14 SAR.Current price is: 799.13 SAR. excl. VAT Save 51.01 SAR

On backorder

Request a Quote
APC

APC AP7821B Metered Rack PDU, 16A, 1U, 8 x C13

Model AP7821B
2 Years1U230V
Original price was: 2,280.36 SAR.Current price is: 2,143.54 SAR. excl. VAT Save 136.82 SAR

On backorder

Request a Quote

Original price was: 2,810.45 SAR.Current price is: 2,641.82 SAR. excl. VAT